Single-channel micropipette Transferpette® S, fixed-volume, DE-M
Overview
- Efficient: one-hand operation
- Flexible: ergonomic design for all hand sizes
Choose your product:
Cat.-No. | Volume range | Model | Accuracy in % (±) | Accuracy in µl (±) | Coefficient of variation (%) | Coefficient of variation (µl) | Recommended tip size | Number of channels |
---|---|---|---|---|---|---|---|---|
705808 | 10 µl | F-10 | 1 % | 0.1 µl | 0.5 % | 0.05 µl | 0,5 - 20 | single-channel |
705816 | 20 µl | F-20 | 0.8 % | 0.16 µl | 0.4 % | 0.08 µl | 2 - 200 | single-channel |
705820 | 25 µl | F-25 | 0.8 % | 0.2 µl | 0.4 % | 0.1 µl | 2 - 200 | single-channel |
705828 | 50 µl | F-50 | 0.8 % | 0.4 µl | 0.4 % | 0.2 µl | 2 - 200 | single-channel |
705838 | 100 µl | F-100 | 0.6 % | 0.6 µl | 0.2 % | 0.2 µl | 2 - 200 | single-channel |
705844 | 200 µl | F-200 | 0.6 % | 1.2 µl | 0.2 % | 0.4 µl | 2 - 200 | single-channel |
705854 | 500 µl | F-500 | 0.6 % | 3 µl | 0.2 % | 1 µl | 50 - 1000 | single-channel |
705862 | 1,000 µl | F-1000 | 0.6 % | 6 µl | 0.2 % | 2 µl | 50 - 1000 | single-channel |
705864 | 2,000 µl | F-2000 | 0.8 % | 16 µl | 0.3 % | 6 µl | 500 - 5000 | single-channel |
Pack of | Price/Pack ₹ | |||
---|---|---|---|---|
Product Detail
The Transferpette® S air displacement pipette allows you to work efficiently and ergonomically with both small and large volumes. Low operating forces and a short stroke ensure relaxed pipetting, even during long pipetting series. Due to its perfect ergonomics, the Transferpette® S provides a comfortable grip in any hand position, whether you are right- or left-handed, or have big or small hands. Changing your grip is not necessary, since the microliter pipette provides true one-hand operation: set the volume, pipette, eject the tip.
The volume-change protection is also easy to operate with gloves on and protects your set volume against accidental adjustment. The Transferpette® S also features Easy Calibration technology, which makes calibration a breeze. Calibration can be carried out without tools. A compatibility table shows which tips fit which device, so that you always order the correct pipette tips.
Limitations of use:
Operating temperature of instrument and reagent should be between +15 °C and +40 °C (59 °F to 104 °F) (other temperatures upon request)
Vapor pressure up to 500 mbar
Viscosity: 260 mPa s
For viscous media, the speed must be adjusted if necessary.
Items supplied
Transferpette® S, fixed-volume model, supplied with performance certificate, shelf mount and silicone grease
Resources
Cat.-No. | Volume range | Model | Accuracy in % (±) | Accuracy in µl (±) | Coefficient of variation (%) | Coefficient of variation (µl) | Recommended tip size | Number of channels |
---|---|---|---|---|---|---|---|---|
705808 | 10 µl | F-10 | 1 % | 0.1 µl | 0.5 % | 0.05 µl | 0,5 - 20 | single-channel |
705816 | 20 µl | F-20 | 0.8 % | 0.16 µl | 0.4 % | 0.08 µl | 2 - 200 | single-channel |
705820 | 25 µl | F-25 | 0.8 % | 0.2 µl | 0.4 % | 0.1 µl | 2 - 200 | single-channel |
705828 | 50 µl | F-50 | 0.8 % | 0.4 µl | 0.4 % | 0.2 µl | 2 - 200 | single-channel |
705838 | 100 µl | F-100 | 0.6 % | 0.6 µl | 0.2 % | 0.2 µl | 2 - 200 | single-channel |
705844 | 200 µl | F-200 | 0.6 % | 1.2 µl | 0.2 % | 0.4 µl | 2 - 200 | single-channel |
705854 | 500 µl | F-500 | 0.6 % | 3 µl | 0.2 % | 1 µl | 50 - 1000 | single-channel |
705862 | 1,000 µl | F-1000 | 0.6 % | 6 µl | 0.2 % | 2 µl | 50 - 1000 | single-channel |
705864 | 2,000 µl | F-2000 | 0.8 % | 16 µl | 0.3 % | 6 µl | 500 - 5000 | single-channel |
Pack of | Price/Pack ₹ | |||
---|---|---|---|---|
Product Detail
The Transferpette® S air displacement pipette allows you to work efficiently and ergonomically with both small and large volumes. Low operating forces and a short stroke ensure relaxed pipetting, even during long pipetting series. Due to its perfect ergonomics, the Transferpette® S provides a comfortable grip in any hand position, whether you are right- or left-handed, or have big or small hands. Changing your grip is not necessary, since the microliter pipette provides true one-hand operation: set the volume, pipette, eject the tip.
The volume-change protection is also easy to operate with gloves on and protects your set volume against accidental adjustment. The Transferpette® S also features Easy Calibration technology, which makes calibration a breeze. Calibration can be carried out without tools. A compatibility table shows which tips fit which device, so that you always order the correct pipette tips.
Limitations of use:
Operating temperature of instrument and reagent should be between +15 °C and +40 °C (59 °F to 104 °F) (other temperatures upon request)
Vapor pressure up to 500 mbar
Viscosity: 260 mPa s
For viscous media, the speed must be adjusted if necessary.
Items supplied
Transferpette® S, fixed-volume model, supplied with performance certificate, shelf mount and silicone grease