MV 10C EX VARIO +AK+EKVARIO® chemistry diaphragm pump
Overview
- full advantage of ATEX chemistry diaphragm pumps with separator AK and emission condenser EK
- VARIO®: short process times due to hysteresis-free VARIO® vacuum control
- VARIO®: VARIO® pump operates on demand only as fast as necessary – minimal power consumption, extended maintenance intervals, silent operation
- VARIO®: vacuum controller VACUU·SELECT (optional) for precise vacuum control and fully automatic processes
- ATEX vacuum sensor and Connection Box 100 for easy installation – from one source
Ultimate vacuum
2 mbar
Ultimate vacuum with gas ballast
10 mbar
Max. pumping speed 50 Hz
8.1 m3/h
VARIO® chemistry diaphragm pump in action
With the new ATEX VARIO® chemistry diaphragm pumps and vacuum systems, the vacuum can be precisely controlled by the motor speed. The VARIO® pump is driven by an additional control signal line. The optional vacuum controller VACUU·SELECT with ATEX vacuum sensor and Connection Box 100 enable fully automatic evaporations without the need for parameter settings or user programming. With the adaptive control it finds the boiling pressure independently and adjusts the vacuum continuously and optimally according to the vapor pressure. The vacuum controller and the Connection Box 100 are installed in a non-hazardous area.
Technical data and graphs
Max. pumping speed 50 Hz | 8.1 m3/h | Select diagram |
Ultimate vacuum | 2 mbar / 1.5 torr | |
Ultimate vacuum with gas ballast | 10 mbar / 7.5 torr | |
Number of heads | 8 | |
Number of stages | 4 | |
Vacuum controller | without controller | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Max. back pressure (abs.) | 1.1 bar | |
Inlet connection | small flange KF DN 25 | |
Outlet connection | Hose nozzle DN 8-10 mm | |
Coolant connection | 2 x hose nozzle DN 6-8 mm | |
Rated motor power | 0.5 kW | |
Minimum motor speed VARIO in min-1 | 30 min-1 | |
Maximum motor speed VARIO in min-1 | 1500 min-1 | |
Rated motor speed at 50/60 Hz | 1500 min-1 | |
Protection class IEC 60529 | IP 54 | |
Dimension L in mm | 651 mm | |
Dimension B in mm | 555 mm | |
Dimension H in mm | 452 mm | |
Weight | 63 kg | |
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) | 42 dBA | |
ATEX conformity | Pumping chamber (pumped gases): II 2G Ex h IIC T3 Gb X, Environment with inert purge gas: II 2G Ex h IIB T4 Gb X, Environment without inert purge gas: II 3G Ex h IIB T4 Gc X, Motor: II 2G Ex db IIB T4 Gb | |
NRTL certification | No | |
Items supplied | Pumping unit with two motors (with control and mains cables at each of the two motors) and inlet separator and emission condenser completely mounted, ready for use, with manual. Shatter and shock protection for glass parts are to be provided by the customer. Speed control via 4-20 mA current loop (4 mA = 0 rpm, 20mA = 1500 rpm). Control signal and mains cable length 10 m, without plugs. | |
Rated mains voltage range 1 | 230 V | |
Mains frequency 1 | 50 Hz |
Downloads
Optional accessories
Related Products
VARIO® chemistry diaphragm pump in action
With the new ATEX VARIO® chemistry diaphragm pumps and vacuum systems, the vacuum can be precisely controlled by the motor speed. The VARIO® pump is driven by an additional control signal line. The optional vacuum controller VACUU·SELECT with ATEX vacuum sensor and Connection Box 100 enable fully automatic evaporations without the need for parameter settings or user programming. With the adaptive control it finds the boiling pressure independently and adjusts the vacuum continuously and optimally according to the vapor pressure. The vacuum controller and the Connection Box 100 are installed in a non-hazardous area.
Technical data and graphs
Max. pumping speed 50 Hz | 8.1 m3/h | Select diagram |
Ultimate vacuum | 2 mbar / 1.5 torr | |
Ultimate vacuum with gas ballast | 10 mbar / 7.5 torr | |
Number of heads | 8 | |
Number of stages | 4 | |
Vacuum controller | without controller | |
Lower ambient temperature (operation) | 10 °C | |
Upper ambient temperature (operation) | 40 °C | |
Lower ambient temperature (storage) | -10 °C | |
Upper ambient temperature (storage) | 60 °C | |
Max. back pressure (abs.) | 1.1 bar | |
Inlet connection | small flange KF DN 25 | |
Outlet connection | Hose nozzle DN 8-10 mm | |
Coolant connection | 2 x hose nozzle DN 6-8 mm | |
Rated motor power | 0.5 kW | |
Minimum motor speed VARIO in min-1 | 30 min-1 | |
Maximum motor speed VARIO in min-1 | 1500 min-1 | |
Rated motor speed at 50/60 Hz | 1500 min-1 | |
Protection class IEC 60529 | IP 54 | |
Dimension L in mm | 651 mm | |
Dimension B in mm | 555 mm | |
Dimension H in mm | 452 mm | |
Weight | 63 kg | |
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) | 42 dBA | |
ATEX conformity | Pumping chamber (pumped gases): II 2G Ex h IIC T3 Gb X, Environment with inert purge gas: II 2G Ex h IIB T4 Gb X, Environment without inert purge gas: II 3G Ex h IIB T4 Gc X, Motor: II 2G Ex db IIB T4 Gb | |
NRTL certification | No | |
Items supplied | Pumping unit with two motors (with control and mains cables at each of the two motors) and inlet separator and emission condenser completely mounted, ready for use, with manual. Shatter and shock protection for glass parts are to be provided by the customer. Speed control via 4-20 mA current loop (4 mA = 0 rpm, 20mA = 1500 rpm). Control signal and mains cable length 10 m, without plugs. | |
Rated mains voltage range 1 | 230 V | |
Mains frequency 1 | 50 Hz |
für Zoom klicken
Max. pumping speed 50 Hz
für Zoom klicken