Product description

MD 4C EX +AK+EK

Chemistry vacuum system

ATEX chemistry vacuum systems are ready for use for applications with large amounts of condensable vapors due to optimally configured accessories. Typical applications are rotary evaporators and drying ovens with potentially explosive atmospheres. The separator at the inlet (AK) retains particles and liquid droplets. The waste vapor condenser at the outlet (EK) is highly efficient and compact. The condenser enables near-100-percent solvent recovery. Included in delivery is a separate gas ballast connection part for use with inert gas.

Information on the disposal of old devices »

Technical Data

Technical data and graphs

Item number 20696931
Max. pumping speed 50 Hz 3.7 m³/h
Ultimate vacuum 3 mbar
Ultimate vacuum in torr 2.3 torr
Ultimate vacuum with gas ballast 10 mbar
Ultimate vacuum with gas ballast in torr 7.5 torr
Number of heads 4
Number of stages 3
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Max. outlet pressure (abs.) 1.1 bar
Inlet connection small flange KF DN 25
Outlet connection Hose nozzle DN 8-10 mm
Coolant connection 2 x hose nozzle DN 6-8 mm
Rated motor power 0.25 kW
Rated motor speed at 50/60 Hz 1500 min⁻¹
Protection class IEC 60529 IP 54
Dimension L in mm 600 mm
Dimension W in mm 365 mm
Dimension H in mm 420 mm
Weight 38.5 kg
Noise (sound pressure level) in dBA at 50 Hz or 1500 rpm/62% (VARIO)/1500 rpm (VARIO-SP)/12500 Upm (VACUU·PURE®) 53 dBA
ATEX conformity Pumping chamber (pumped gases): II 2G Ex h IIC T3 Gb X Environment with inert purge gas: II 2G Ex h IIB T4 Gb X Environment without inert purge gas: II 3G Ex h IIB T4 Gc X Motor: II 2G Ex db IIB T4 Gb
NRTL certification No
Items supplied Pumping unit completely mounted with inlet separator and emission condenser, with manual, 10 m cable without plug. Shatter and shock protection for glass parts are to be provided by the customer.
Rated mains voltage range 1 230 V
Mains frequency 1 50 Hz
Items supplied